Pump
Create Function
Component Table Data
net.pump
Parameter |
Datatype |
Value Range |
Explanation |
name |
string |
Name of the pump |
|
from_junction |
integer |
\(>\) 0 |
Index of junction at which the pump starts |
to_junction |
integer |
\(>\) 0 |
Index of junction at which the pump ends |
std_type |
string |
The selected standard type for the pump. Can be found in net.std_type. |
|
in_serivce |
boolean |
True / False |
True for in service or False for out of service |
type |
string |
Type variable to classify the pump |
Physical Model
The pump is used to lift the pressure of a fluid flowing therethrough. The pressure rise depends on pump specific technical product properties setting flowrate and pressure in correlation. Thus, by given flowrate the pressure lift can be calculated. There are three different standard types defined by default (P1, P2, P3). However, the user can easily extend the standard type list.
In pandapipes the pump is considered as branch element with zero length (pumps are considered ideal). Thus it behaves and is considered accordingly.
Result Table Data
net.res_pump
Parameter |
Datatype |
Explanation |
deltap_bar |
float |
The pressure lift caused by the pump [bar] |