Heat Exchanger

Create Function

create_heat_exchanger(net, from_junction, to_junction, diameter_m, qext_w, loss_coefficient=0, name=None, index=None, in_service=True, type='heat_exchanger', **kwargs)

Creates a heat exchanger element in net[“heat_exchanger”] from heat exchanger parameters.

Parameters
  • net (pandapipesNet) – The net within this heat exchanger should be created

  • from_junction (int) – ID of the junction on one side which the heat exchanger will be connected with

  • to_junction (int) – ID of the junction on the other side which the heat exchanger will be connected with

  • diameter_m (float) – The heat exchanger inner diameter in [m]

  • qext_w (float, default 0.0) – External heat feed-in through the heat exchanger in [W]

  • loss_coefficient (float) – An additional pressure loss coefficient, introduced by e.g. bends

  • name (str, default None) – The name of the heat exchanger

  • index (int, default None) – Force a specified ID if it is available. If None, the index one higher than the highest already existing index is selected.

  • in_service (bool, default True) – True for in_service or False for out of service

  • type (str) – Not used yet

  • kwargs – Additional keyword arguments will be added as further columns to the net[“heat_exchanger”] table

Returns

index - The unique ID of the created heat exchanger

Return type

int

Example
>>> create_heat_exchanger(net, from_junction=0, to_junction=1, diameter_m=40e-3, qext_w=2000)

Component Table Data

net.heat_exchanger

Parameter

Datatype

Value Range

Explanation

name

string

Name of the heat exchanger

from_junction

integer

\(>\) 0

Index of junction at which the heat exchanger starts

to_junction

integer

\(>\) 0

Index of junction at which the heat exchanger ends

diameter_m

float

\(\gt\) 0

Equivalent inner diameter of the heat exchanger [m]

qext_w

float

The heat flow entering or leaving the heat exchanger [W]

loss_coefficient

float

\(\geq\) 0

An additional loss coefficient which might account for e.g. bends

in_service

boolean

True / False

Specifies if the heat exchanger is in service.

type

string

Type variable to classify heat exchangers

Result Table Data

net.res_heat_exchanger

Parameter

Datatype

Explanation

v_mean_m_per_s

float

The mean velocity of fluid in the heat exchanger [m/s]

p_from_bar

float

Pressure at “from”-junction [bar]

p_to_bar

float

Pressure at “to”-junction [bar]

t_from_k

float

Temperature at “from”-junction [K]

t_to_k

float

Temperature at “to”-junction [K]

mdot_from_kg_per_s

float

Mass flow into heat exchanger [kg/s]

mdot_to_kg_per_s

float

Mass flow out of heat exchanger [kg/s]

vdot_norm_m3_per_s

float

Norm volume flow [m^3/s]

reynolds

float

Average Reynolds number